中文版 English
 
 
Coating Thickness Gauge    Temperature & Humidity Measuring Gauge     Surface Cleanliness     Standard & Inspection Manual
Surface Profile Gauge     Adhesion Tester    Pinhole & Porosity Detection     Hardness Tester
Color / Gloss Meter    Steel Thickness Gauge    Gas Detector     Lab. Instrument
BRESLE-KIT
Product Information
User-friendly test-kit for assessing the presence and level or soluble salts on blast-cleaned surfaces prior to coating. This unique method conforms to ISO8502-6 and 9 standards displays the results in milligram per square meter.
The test-kit consists or a digital conductivity meter, 20 Bresle Samplers, disposable cups and all other accessories.
The kit also contains the equipment to determine the contamination or the blast-media in use.
134A Chloride Ion Test Kit for Abrasives
Product Information
Chlorides deposited on a surface by contaminated abrasive during blasting can cause a coating to fail prematurely. Contamination can build up, particularly if the blast media is recycled several times.
134A is an easy to use, accurate field test which determines if your abrasive is contaminated with chlorides and thus prevent costly surface-related failures.
Chloride Ion testing can now be achieved quickly and accurately using a novel extraction method, based on the CHLOR*EXTRACT? solution.
134S Salt Detection Kit for Blast Cleaned Surfaces
Product Information
Chloride Salts left on the surface before the first coat is applied can result in the coating system being forced off the surface by corrosion or blistering before the full life of the coating has been reached.
To ensure that the chloride has been removed it is essential that the surface is tested before the coating is applied.
134W Chloride Ion Test Kit for Water/Liquids
Product Information
Coatings can fail due to chlorides being deposited on a surface by contaminated water during pressure washing, UHP water jetting or wet abrasive blasting.
The Elcometer 134W is an easy to use, accurate, field based test which determines if your wash water is contaminated with chlorides and thus prevent costly surface coating failures. It can also be used to monitor the recycled water (after it has been applied) to establish how effectively salt removal is occurring.
134 CSN-Chlorides, Sulphates and Nitrates test
Product Information

All the components of the CSN Test Kit are pre-measured and pre-dosed for complete Accuracy: All results are recorded in parts per million (ppm)-no complicated calculation needed to transfer these to μ gcm-2 as the tests of the 134CSN are designed to use a ratio of 1:1

Together with:

5xChloride Tests

5xTest,togher with 1 xColorimenter, for Sulphate Testing

5xNitrate Test Strips

5xSyringes ( without needs )

Comductivity Meter
Product Information
》Model: EcTestr11+

》With 3 ranges as follows:

Range Resolution
0-200µs/cm 0.1µs/cm
200-2000µs/cm 1.0µs/cm
2000-20000µs/cm 0.01ms/cm

 

Bresle patch
Product Information

Background
Surface contaminants, such as salt, may cause major problems and increase maintenance costs for vessels, industry buildings and steel structures in general. Coating failure such as blistering and corrosion may be the result of a too high level of salt prior to painting. The Bresle method is commonly used to measure the level of surface salts.

Sampling and measurement
For sampling, a so-called Breslepatch is used, according to a method described in the International Standard ISO 8502-6. The chemical analysis the sampling solution can be analysed in various ways, one quick way to do this on-site is by conductivity as described in ISO 8502-9.

Equipment
All you need for sampling is Breslepatches, a syringe and needle, deionised water and a beaker/measuring glass. For the analysis you also need some kind of instrument, for instance a conductivity meter. In our kit you will find all you need for a complete measurement of total soluble salts according to ISO 8502-9.

130 SCM400 Salt Contamination Meter
Product Information
Soluble salts on a surface are absorbed into a special filter paper soaked with distilled water. The Elcometer 130 measures the conductivity of the wet paper, calculates the salt level and displays it in ug cmˉ2 .
Suitable for a wide range of shapes, orientations and surfaces and finishes
Quick and simple to use
Battery operated and portable
Confirms adequate cleaning of surfaces before coating, aiding the prevention of premature coating failure
Shows salt build-up on vulnerable surfaces which can be cleaned to increase the lifetime of a coating
Test papers can be re-moistened and a similar test result can be achieved - ideal for proof and ISO requirements
Accurate
Repeatable
Reproducible
Each instrument is supplied in a convenient light weight carry case and includes:

100 High Purity Sample Papers 250ml Pure Water
8 Replacement Plate Support Pads 20 PVC Storage Bags
Disposable Gloves Battery Tissues
3 x 2 ml Syringes Plastic Tweezers

 
Product [ Blast Equipment | Vacuum Equipment | Spray Equipment | High Pressure Water Cleaner | Inspection Instrument | Weary Material | Color Card ]
www.freeland.org.cn
Print
Copyright © 2006  Shanghai Freeland International Trading Co. Ltd.
Add:  No.368-388 Henmianjiang Road,zhangjiang Pudong,Shanghai,China :201210P.R. China
Tel:021-50343622 50346344   Fax:021-38710119    E-mail:info@shfreeland.com
 